Tailored Electrical Contractors (TEC) provides Electrical Installation Condition Reports (EICRs) and electrical inspection and testing services for commercial, industrial and domestic premises. As an NICEIC Approved Contractor, we assess existing fixed electrical installations, identify potential safety risks and report on defects or deterioration requiring attention.
Whether you manage a commercial property, operate an industrial facility, own rental accommodation or need an inspection of your home, our electricians can discuss the testing requirements, explain the report findings and advise on appropriate next steps. Request an EICR quotation.
What Is an Electrical Installation Condition Report (EICR)?
An Electrical Installation Condition Report (EICR) records the findings of periodic inspection and testing of an existing electrical installation. It assesses the installation’s condition for continued use, identifies defects and potential electrical safety risks, and documents inspection and test results, observations, limitations and classification codes.
The inspection assesses the installation against relevant requirements of BS 7671, the IET Wiring Regulations. An older installation does not automatically need replacing solely because it was installed to an earlier edition of the regulations.
What Does an EICR Inspection Check?
Depending on the agreed scope and the installation, an EICR can examine:
- Consumer units, distribution boards, circuit breakers, RCDs and other protective devices.
- Earthing and protective bonding arrangements.
- Fixed wiring, circuits, sockets, switches and lighting connections.
- Signs of overheating, deterioration, damage and unsafe alterations.
- Appropriate checks such as continuity, insulation resistance, polarity and protective measures.
It covers the fixed electrical installation. Portable appliance testing (PAT) and dedicated emergency lighting testing are separate activities and are not automatically included.
Who Requires EICR Testing?
Landlords and Rental Properties: In England, applicable electrical safety regulations require qualifying rented properties to have fixed electrical installations inspected and tested at least every five years, or sooner where the report specifies a shorter interval.
Landlords must provide the latest report to tenants and other parties as required, and arrange necessary remedial action within the applicable timescales.
A new EICR is not automatically required at every change of tenant if an existing report remains valid and the installation is safe.
Businesses and Commercial Spaces: Commercial and industrial duty holders need to manage electrical safety in workplaces and premises under their control.
An EICR can reveal deterioration, defects and risks in fixed installations across offices, shops, warehouses, manufacturing facilities and operational buildings.
The inspection interval depends on the installation’s use, condition, environment, previous findings and relevant risk assessment, rather than one universal five-year rule.
Homeowners: An EICR can help you understand the condition of your home’s electrical installation, especially when purchasing a property, planning renovations or investigating concerns about older wiring.
There is no general requirement for owner-occupiers in England to obtain an EICR every five years, but periodic inspection can support sensible electrical safety maintenance.
| EICR Testing Recipients | Why It’s Required |
|---|---|
Landlords | Legal requirement, tenant safety |
Businesses | Employee and customer safety, compliance |
Homeowners | Safety assurance, issue prevention |
TEC provides electrical inspection and testing services across its stated service areas. To find regional EICR information, use the county and area links in the EICR Testing Available Nationwide section below. If you need advice about an inspection or the findings of an existing report, contact TEC with your property details.
Benefits of Periodic Electrical Inspection
Regular electrical inspection and testing gives property owners, facilities managers and duty holders a clearer picture of their fixed installations:
- Electrical safety: Identify potentially dangerous defects or deterioration.
- Maintenance planning: Prioritise repairs and investigate developing issues.
- Risk management: Document findings to support electrical safety responsibilities.
- Operational planning: Arrange necessary work around business activities where practical.
- Record keeping: Maintain inspection and testing history.
An EICR records the installation’s condition at the time of inspection, subject to stated limitations. It is not a guarantee that faults cannot develop afterwards.
What Does EICR Testing Involve?
1. Agree the scope: We discuss the premises, installation, access, previous reports and operational restrictions.
2. Visual inspection: Accessible parts of the fixed installation are checked for damage, deterioration, overheating and other potential safety concerns.
3. Electrical testing: Appropriate tests assess circuits and protective measures. Some tests require safe isolation, so we discuss likely interruptions in advance, especially for operating businesses.
4. Record the findings: Your EICR documents inspection and test results, observations and any limitations.
5. Explain the next steps: We talk you through the report, including any further investigation or remedial work required.
EICR Testing for Businesses
For larger commercial and industrial installations, the practical arrangements matter as much as the report itself. We can discuss distribution board locations, circuit schedules, essential systems, access restrictions and suitable periods for safe isolation.
We work with facilities teams and other responsible personnel to agree an inspection scope that takes account of the premises and their operations. The report can then help prioritise any defects and plan the next stage of electrical maintenance or repairs.
EICR Testing for Landlords
For landlords and managing agents, the key questions are whether the existing EICR remains suitable, what the latest report says and whether any required remedial work has been completed and documented.
Provide your previous report, if available, together with the property details. We can discuss the inspection requirements, access arrangements and next steps. Applicable legal duties include providing reports and addressing relevant findings within the required timescales.
Understanding EICR Classification Codes
Each observation on an Electrical Installation Condition Report is assigned a code indicating the nature and urgency of the issue:
| Code | Meaning |
|---|---|
| C1 | Danger present. Immediate action required. |
| C2 | Potentially dangerous. Urgent remedial action required. |
| C3 | Improvement recommended. |
| FI | Further investigation required without delay. |
An EICR with C1, C2 or FI observations will normally be assessed as unsatisfactory. A C3 observation alone does not make the report unsatisfactory.
What happens next? An unsatisfactory result does not automatically mean a complete rewire. The work required depends on the specific findings. We can explain the issues, discuss repairs or further investigation and provide a separate quotation where appropriate.
EICR, Electrical Certificates and Other Testing
An EICR assesses the condition of an existing fixed electrical installation. It is not the same document as an Electrical Installation Certificate (EIC), normally issued for new installation work or certain additions and alterations.
Portable appliance testing (PAT) and dedicated emergency lighting inspections are also separate services, not automatically included within an EICR. Tell us if you require these alongside fixed wire inspection and testing so we can discuss the appropriate scope.
Why Choose TEC for EICR Testing?
TEC provides EICR inspection, testing and associated electrical contracting services for homeowners, landlords, commercial premises and industrial facilities. As an NICEIC Approved Contractor, we can assess existing installations, explain the findings and discuss appropriate next steps.
We plan inspection access and potential interruptions with the needs of occupied and operational premises in mind. To request a quotation, provide the property location, premises type, approximate size and, where available, previous EICRs or distribution board and circuit information. Contact TEC about an EICR.
How to Get Started
Getting started with Tailored Electrical Contractors is simple. Whether you need electrical services for a commercial property, industrial facility, or residential home, our team is here to help.
- Contact Us: Reach out to us via phone, email, or our website to schedule an initial consultation. We will discuss your needs and provide a free, no-obligation quote.
- Please schedule an Appointment: We will work with you to find a convenient time for the work to take place, ensuring minimal disruption to your operations.
- Receive Expert Service: Our qualified electricians will conduct all works with precision and care.
- Enjoy Peace of Mind: With Tailored Electrical Contractors, you can rest assured that your electrical systems are safe, compliant, and in expert hands.
Get in Touch
Frequently Asked Questions
An Electrical Installation Condition Report (EICR) records an inspection and appropriate testing of an existing fixed electrical installation, including findings, limitations and any defects or risks identified.
An EICR helps property owners and duty holders identify risks, plan maintenance and document the condition of fixed wiring and electrical equipment forming part of the installation. Statutory requirements depend on the property and circumstances.
Inspection frequency depends on the installation’s type, use, condition, environment, previous findings and applicable requirements. Qualifying rented properties in England are generally subject to inspection at least every five years, or sooner where specified. There is no universal five-year rule for every commercial installation, nor an automatic new EICR requirement at each tenancy change.
An EICR includes inspection and appropriate testing of the fixed installation, such as wiring, distribution boards, protective devices and circuits, within an agreed scope. It does not automatically include portable appliance testing or a separate emergency lighting inspection.
The duration depends on the number of circuits and distribution boards, accessibility, size and complexity of the installation and any operational restrictions. We discuss access and possible power interruptions before the inspection.
Pricing depends on premises type, installation size and complexity, number of circuits and distribution boards, access and the agreed scope. Contact TEC for a quotation.
EICR TESTING AVAILABLE NATIONWIDE
- Avon
- Bedfordshire
- Berkshire
- Buckinghamshire
- Cambridgeshire
- Cheshire
- Cornwall
- Cumbria
- Derbyshire
- Devon
- Dorset
- Durham
- Essex
- Gloucestershire
- Greater London
- Hampshire
- Herefordshire
- Hertfordshire
- Isle of Wight
- Kent
- Lancashire
- Leicestershire
- Lincolnshire
- Merseyside
- Norfolk
- Northamptonshire
- Northumberland
- Nottinghamshire
- Oxfordshire
- Rutland
- Schools
- Shropshire
- Somerset
- Staffordshire
- Suffolk
- Surrey
- Sussex
- Tyne and Wear
- Warwickshire
- West Midlands
- Wiltshire
- Worcestershire
- Yorkshire